clean room airflow visualization

Clean Process Technology, services the establishment, certification and optimization of Controlled Environments for all sectors, Cleanroom, Laminar Flow Unit and Isolator Certification Controlled Environment Surveys, including ESD, Click below to watch a short Airflow New York - UpstateCrowthorne Hi-Tec Services are not designers or builders of cleanroom or cleanroom equipment and therefore provide a completely unbiased report on the performance achieved. We can service and validate a variety of cleanroom and clean air systems from multiple suppliers in a single convenient package. Types of Clean Room Facilities Pharmaceutical: Aseptic suites, Pharmacies / Radio Pharmacies Microelectronic facility validation in accordance with design briefs PSU, CSSD and Mortuary Departments HEPA filter supply, installation and certification We carry out commissioning and validation of all cleanroom facilities from small hospital pharmacies to multimillion pound pharmaceutical production or micro-electronics class 1 facilities.
All tests are undertaken in accordance with the latest standards [cGMP, National and International standards], using the latest test equipment calibrated to National Standards.air duct cleaning adrian mi In fact we can undertake any validation procedures associated with clean room commissioning for the micro-electronic, pharmaceutical and allied industries.lasko performance air cleaner We can service and validate all types of clean air equipment including microbiological safety cabinets, fume cupboards, compressed air supplies, LEV systems, laminar flow equipment and isolators. msds sheet for 3m brake cleanerCombining servicing of equipment and facility into a single service package can reduce downtime and save costs.
Setting room over pressure gradients Calibration of magnehelic gauges and pressure sensors Record light levels [were specified] Noise level readings (inc. octave band analysis as dB(lin), dB(A),‘NC’ or ‘NR’ curves) Check operation of control systems Airborne particle counting (from 0.1 to 25mm) Inspect pre-filter [replace as required] Filter integrity testing (including DOP, PSL and ambient challenges) Temperature and humidity recording (single point or data logging) Structural induction leak checking Issue a report of resultsYou don't have permission to access /2054.html We provide various clean rooms for electronics industries such as semiconductors, display panels, and nanotechnology, based on our unique total clean technology. What is a clean room? Air flow control technology The air flow in the clean room is controlled at the appropriate level through air flow simulations or air flow visualisation tests.
We carry out cleaning diagnosis using advanced measurement and analysis instruments. Control of chemical contamination The appropriate environment is maintained within the clean room by minimizing chemical contaminants using various measurement and analysis technologies. We provide time and cost efficient clean room renovation services to improve the function of existing facilities. Building air conditioning systems Products & Services (Global)Cleanroom Solutions from Concept Smoke Systems Concepts Cleanroom Solution range offers: Aerosol generators for HEPA filter & ULPA filtration testsParticle sizes of just 0.2mmd micronStainless Steel as standardSmoke generators for Filter Integrity Testing (DOP)Air flow Visualisation testing / Particle recovery work The correct functioning of HEPA filters is normally tested at the time of installation, as well as part of the routine maintenance programme. It is normally recommended that HEPA filters are checked at 14 month intervals or less, or immediately after filter changing.
Where high efficiency filters are fitted, it is vital that the filter housing/sealing device does not allow particulate material to pass and thereby compromise the cleanroom environment that is being served. Testing is necessary since HEPA filters can become partially or totally blocked, rendering the filter of little value. The Filter Integrity Test, which uses smoke as a detection method, is usually referred to as a DOP test. This is because the original smoke chemical used for this test was made using  Di-Octyl Phthalate. However, as this substance was suspected to be a carcinogen, pharmaceutical grade white mineral oil is now used with identical results. The new smoke and aerosol generators in Concepts "Cleanroom Solutions" range are used throughout the world by major blue chip pharmaceutical, nuclear and cleanroom specialists for their HEPA filter, ULPA filtration testing, air flow visualisation work and particle recovery tests. For Air Flow Visualisation and particle recovery work, our portable, water based MiniColt 4S generators are ideal as they enable the tester to move from one part of the room to another, making smoke, in order to ‘see’ if the flow of air is correct, this system can also be ducted.
Concepts BS EN ISO 9001:2008 scope is - "Design, manufacture and supply of non-toxic smoke generating equipment and aerosol generating equipment for scientific, military, security and industrial use. Over the years Concept have designed and manufactured many "specialised" projects, so let us know if you have any unique requirments. Concept offer an unbeatable service when it comes to pre-sales advice, quality of product and aftersales care. For HEPA Filter Testing VC Aero aerosol generator For Air Flow Visualisation Concept AirTrace 12v system Concept Aerotech Smoke Wand  MiniColt 4S The Concept Cleanroom range is used for the following applications: CleanroomsHEPA FiltersULPA FiltersHVAC SystemsLEV TestsSurgical SuitesNuclear Lab'sResearch & Development Lab'sSurgical SuitesVentilation TestsExhaust extraction MiniColt 4S - Clean Room Concept Aerotech Smoke Wand Clean Room Overview Brochure > view all articles Colt 4 Twin Turbo - New Product