hoffman air purifier

Hoffman is excited to announce the launch of the new PROLINE G2, the next generation modular solution. PROLINE G2 is designed to bear the advanced loads and harsh environments of industrial applications, while making the electrical enclosure easier to use and faster to populate. Learn More about ProLine G2 At Hoffmann Filter Corporation, we pride ourselves on carrying the most extensive line of filtration solutions available in the industry. With a number of options for all of our systems, we're confident that we can customize a solution to meet your exact needs. HSF Suction Belt Filter UBF Suction Band Filter TBF Deep Bed Band Filter BFI Flat Bed Band Filter We have a rotating inventory of used filter systems that are available for sale as fully re-furbished systems. Hoffmann also actively buys back useable used machinery from our customers. Systems currently available include: Welcome to Hoffmann Filter Corporation! At Hoffmann Filter Corporation, we pride ourselves on our broad product line and exceptional customer service.

Our filters are custom-designed to meet your exact needs, and we have solutions available for a wide range of industries. We work closely with our customers to insure that from the time we quote until long after your filter is up and running, we are "Your Partner in Filtration."
c50 air cleaner cover New sales partner for the Southwest U.S. - click here for more informaton
filtrete ultra quiet room air purifier Hoffmann completes project for major automotive manufacturer
abc air duct cleaning orlando Hoffmann Filter Corporation has now designed and supplied filters for all of the major US auto manufacturers. Pictured below is a UBF-1200 delivered in spring 2014. Hoffmann expands US manufacturing operations

Hoffmann Filter Corporation has recently purchased a second building in New Hudson, MI - close to our main manufacturing facility in Brighton, MI. The new addition will allow Hoffmann to take on even more projects catered to customers across a variety of industries. Request a 2016 Catalog W X Y Z Phone and Mail Orders Cleaning Accessories and Supplies A system which complies with OSHA Regulations and minimizes Occupational Exposure To Toxic Vapors. The System that destroys the odors and fumes and doesn't just mask them. Toxic vapors are reduced as well!! Lab-Air Units are designed to eliminate harmful fumes and annoying odors from the laboratory workplace. How do they work ? Electronic Air Purifiers produce a controlled level of Ozone electrically by converting molecules of Oxygen (O2 ) into molecules of Ozone (O3). Ozone, sometimes called activated oxygen, as part of the process of returning to oxygen, casts off its extra atom. That extra atom combines with the molecule of the odor's source and thereby destroys the odor by oxidation.

Once Ozone's extra atom is consumed fresh air is left behind which was created by a natural process. Lab-Air Units produce a safe unsaturated level of activated oxygen that neutralizes harmful fumes and eliminates problem odors from organic materials as well as some commonly used chemicals such as: Formaldehyde, Xylene, Toluene, Glutaraldehyde, Alcohol, Acetone. Formic Acid + Oxygen Formic Acid + Ozone CO2 + H2O + O2 Carbon Dioxide* + Water* + Oxygen* * All Harmless Gases (American Institute of Technology) What is the best location for our LAB-AIR* System ? Histology/Pathology/EM Labs – There are common odors and toxic vapors which are generated by fixing fluids, staining and embedding materials, autopsy samples, body odors, remains of dead animals and fumes which can exceed the capacity of the fume hood. In these cases these fumes may spread to other areas of the building. Other Labs with Odors – There are other locations within the hospital or research lab where people are using chemicals such as xylene, glutaraldehyde, formaldehyde, etc. where the LAB-AIR* SYSTEM would be very beneficial.

Animal Necropsy – These are odors and fumes associated with the remains of dead animals. These odors can spread, especially in the warmer months, throughout an entire building. The LAB-AIR SYSTEM eliminates this totally. Lab-Air's Electronic Air Purifiers are CSA approved and come with a two year warranty. Powered by 110 VAC, 60 Hz or 220 VAC, 50 Hz. 2,500 milligrams ozone per hr 14" L x 15" W x 5.5" H Has an adjustable ozone output; provides up to 980mg/hr. Multiple option timer: 15 min, 30 min, 1 hr, 2 hr, 4 hr, and continuous operation settings. It comes with non-slip feet and power cord. It measures 14" L x 10" W x 7" H. Weight: 13 lbs High output – has a 220 CFM fan Lab-Air Model PA 2500 Lab-Air Model PA 1200 Cleaning Kit for Model PA 2500 Cleaning Kit for Model PA 1200 AREA x ODOR FACTOR = MG/HR required Measure the Cubic Footage (L x W x H) of the AREA being treated. Estimate the ODOR FACTOR as follows:

Light Odor Factor = 0.005 Medium Odor Factor = 0.018 Strong Odor Factor = 0.036 Light Odor Factor = 0.18 Medium Odor Factor = 0.65 Strong Odor Factor = 1.29 Multiply the AREA by the ODOR FACTOR to determine the MG/HR on the chart below. Set OZONE on the machine to the setting nearest the required MG/HR and adjust as required. MG/HR (Milligrams per hour in dry air) Laboratory Cleaning Solutions and SuppliesSouth Carolina Camfil - Greg Herman A Camfil: Regional Sales Manager103 38th StreetBirmingham, AL US 35222 Phone: + 1 205.482.0909 Air Filter Service Company : A Camfil Branch Location A Camfil: HVAC Distributor. Air Filter Service Company provides replacement filters for the entire States of SC and NC including the metro areas of Charlotte, Raleigh, Wilmington, Columbia, and Greenville.P.O. Hoffman & Hoffman - Greenville A Camfil: Cleanroom Representative HVAC Representative Safety & Protection Representative95 Marcus DriveGreenville