honeywell 60001 air purifier

9.Do not use air purifier where combustible gases, vapors or an SAFETY oxygen rich environment are present. 10. Do not expose the air purifier to rain, INSTRUCTIONS or use near water, in a bathroom, laundry area or other damp location. Filter Basket SET-UP • Select a firm, level and flat location. For proper air flow, locate the unit at least 3 feet (1 M) from any wall or furniture. • Ensure the exit grill faces away from the closest wall or furniture. • Press the toggle arrows to your desired number of hours (1 through 10). The selected number will flash for a few seconds -- once it stops flashing, the air purifier is in Timer Mode. (Example: If you want the unit to turn off in 6 hours, touch the timer button, then press the arrow button until the number "6"... Rear Door is removed. CLEANING AND MAINTENANCE • Use a clean, dry cloth to wipe the external surfaces of the air purifier. DO NOT USE WATER, GASOLINE, POLISH, OR ANY CHEMICAL SOLUTION. • The IFD filter and pre-filter should be cleaned at least once a month, or sooner depending on the air quality of the room (See “Removing/Cleaning the IFD Filter”...

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST, RETURN THE AIR PURIFIER TO THE ORIGINAL PLACE OF PURCHASE OR SEE YOUR WARRANTY. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF, DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE AIR PURIFIER OR PERSONAL INJURY.Éviter de laisser l’appareil à la pluie ou de le faire fonctionner à proximité de l’eau, dans une salle de DE SÉCURITÉ bains, une salle de lessive ou dans tout autre endroit humide. • S'assurer que la grille de distribution n'est pas dirigée vers un mur ou un meuble. • S'assurer qu'aucune des grilles n'est obstruée. • Brancher l'appareil dans une prise de courant mise à la terre de 120 V. Consulter la section intitulée IMPORTANTES INSTRUCTIONS DE SÉCURITÉ. La barre de filtre passe de la position « IFD» à la position « Dirty » (Sale) à mesure que la durée de service du filtre diminue. ÉVITER D'UTILISER DE L'EAU, DE L'ESSENCE, DU PRODUIT À POLIR OU TOUTE SOLUTION CHIMIQUE.

• Le filtre IFD et le préfiltre devraient être nettoyés au moins une fois par mois, ou plus souvent, selon la qualité de l'air de la pièce dans laquelle fonctionne le purificateur d'air (Consulter les sections «...
air purifier ac4012 Southborough, MA 01772 Prière de spécifier le numéro de modèle.
surround air xj-3800 intelli-pro air purifier user manualREMARQUE : EN CAS DE PROBLÈME, CONTACT LA SERVICE À LA CLIENTÈLE PREMIÈREMENT, RETOURNER L'APPAREIL À L'ENDROIT OÙ IL A ÉTÉ ACHETÉ OU CONSULTER LA GARANTIE.
air purifier ae101PRIÈRE DE NE PAS TENTER D'OUVRIR VOUS- MÊME LE BOÎTIER DU MOTEUR, CE QUI POURRAIT ANNULER LA GARANTIE ET... 16. No se siente ni se pare sobre el purificador 5. No debe usar el aparato si el enchufe o el de aire, ni coloque objetos pesados cable eléctrico están dañados.

• Escoja un lugar firme, nivelado y plano. Para obtener un flujo de aire adecuado, coloque la unidad por lo menos a 3 pies (1 metro) de distancia de la pared o de los muebles. • Verifique que la rejilla de salida esté mirando en dirección opuesta a la pared o al mueble más cercano. Este purificador de aire IFD viene equipado con un monitor electrónico del filtro que proporciona una guía conveniente para la limpieza del IFD y del pre-filtro en base a las horas de uso y al nivel de potencia del purificador de aire. Esto es beneficioso debido a que la vida útil del filtro depende de la cantidad de aire y de las sustancias contaminantes que pasen por el mismo. AGUA, GASOLINA, PRODUCTOS LUSTRADORES, NI SOLUCIONES QUÍMICAS. • Es necesario limpiar el filtro IFD y el pre-filtro por lo menos una vez al mes o con mayor frecuencia, según la calidad de aire de la habitación. (Consulte las secciones de “Remoción y limpieza del Filtro IFD”... Southborough, MA 01772 Por favor, especifique el número de modelo.

NOTA: EN CASO DE PROBLEMA, CONTACTO SERVICO A LA CLIENTELA PRIMERO, DEVUELVA EL PURIFICADOR DE AIRE AL COMERCIO DONDE LO COMPRÓ O CONSULTE LA GARANTÍA. NO INTENTE ABRIR EL CAJETÍN DEL MOTOR, PODRÍA ANULAR LA GARANTÍA Y CAUSAR DAÑOS MATERIALES O CORPORALES.Manuals Brands Honeywell Manuals Air Cleaner 60001 - Enviracaire Grade Air Purifier Manuals and User Guides for Honeywell 60001 - Enviracaire Grade Air Purifier. We have 1 Honeywell 60001 - Enviracaire Grade Air Purifier manual available for free PDF download: Important Safety Instructions Manual Electrostatic air filtration is another name for the electrostatic precipitator (ESP). Ionic Breeze wss one very popular "ionic" air purifier using ESP filtration technology, Freidrich C90b was another. Neither of these air cleaners survived the ozone shake out, but they still serve as leading examples of the electrostatic type air cleaner. ESPs generally do NOT have HEPA filters, they impart a charge to incoming

particulate, causing it to stick to an oppositely charged metal grid. ESPs are efficient cleaning devices that offer less restriction to air flow than HEPA filters. They can remove fine particulates to .01 micron when properly maintained. Electro-static filtration is common in industrial particulate emissions applications. Its adaptation to residential air cleaning has a few problems. An ESP charges the air in it with a very powerful electric field, creating ionized particles. Oppositely charged metal collector plates, often made of stainless steel, attract and collect most of the particles in the air stream. ESP air cleaners run at high voltages. ”I was working in the lab late one night, When my eyes beheld an eerie sight, For my monster from his slab began to rise, And suddenly, to my surprise” The electrically charged nature of this group raises several issues in my mind: these suggest theme lyrics from the 1962 pop hit “Monster Mash” by Bobby "Boris" Pickett.

Some plate precipitators, such as the once popular Ionic Breeze, are completely filterless. Others, like the Friedrich C90 series, will have a pre-filter and a post filter with some carbon. The first ESP filtration issue is: as dirt accumulates, the efficiency of the unit dramatically declines, the dirt electrically insulates the collector plate. Then newly charged particles don’t stick, re-entering the room, sticking to hair, carpet, furniture, clothes and lungs. The efficiency of electrostatic air filtration can drop 20% in the first few days after plate cleaning. If the collection plates are left unwashed, the dirt may stick to the metal so that heavy scrubbing is needed to clean them. Other parts inside the air cleaner may also get gummed up. I gave my son a Honeywell 60001, which uses ESP filtration, collecting particles on a honeycomb grid. If not rigorously cleaned it bypasses. He ran the 60001 for three years in a dirty apartment, THEN we cleaned it.

The entire interior of the Honeywell electrostatic was coated with black soot. Some consumer ESP’s are offered with special soak-off cleaners, which soak the plate overnight, to loosen the tightly bound particulates. When some models with electro-static air filtration get dirty, they begin to arc across the plates, making a sharp crackling pop. This was a common problem with the Friedrich unit. Popping can be a very frequent and annoying reminder that cleaning has been neglected. This is not loud like HEPA units, but many owners complain. Among Sharper Image Ionic Breeze's few credits is the fact that it doesn't pop, making only a minor hum. Electronic air filtration removes only particles, having no effect on gas phase VOC pollutants. As my readers know, I consider this a fatal flaw. ESPs are rarely used by the scientific or medical communities where clean air is critical. The zombies were having fun, The party had just begun!

Many common electronic products including copy machines, televisions, and hair dryers, produce trace levels of ozone. ESPs can produce substantial ozone. There are government safety standards for ozone in other settings. 50 parts-per-billion (ppb)concentration (equals .050 parts per million)is the established limit for indoor medical devices. CARB (California Air Resources Board) has excluded a list of air cleaners which exceed .050 parts per million. Most ESP air filtration units crowd or exceed the 50 ppb medical device/CARB air cleaner limit. In a Consumer Reports two-inch (from device output) ozone test in the open lab, the Surround Air XJ-2000 produced the most ozone, 319 ppb, followed by the IonizAir P4620 at 168 ppb, the Ionic Breeze at 48 ppb, the Ionic Pro CL-369 at 33 ppb and the Brookstone Pure-Ion at 26 ppb. In the three-feet open lab test, the Brookstone emitted the least ozone of the ionizers at 2 ppb, and the IonizAir producing the most at 28 ppb.

Ozone is a strong oxidizing agent: when we take anti-oxidant vitamins to protect our health, why add unnecessary oxidants to our air? I do not accept the idea that low levels of ozone can safely be added to the list of toxins and oxidants we already breathe. Some electronic air filtration air purifiers, including Ionic Breeze, but not Friedrich, charge particles positively and collector plates negatively. Positive ions were implicated in the original ion research as the bad guys. Negative ions were the source of claimed health benefits before the feds banned such claims. I have seen no tests, but it seems to me like dirty ESP ionic air purifiers might be dumping positive ions. I am concerned that the strong electrical fields used to charge the particles in ESP air filters may be more harmful to health than competing technologies. Of course, my 120 volt AC purifiers, clocks, and fans are kept far away from my head while I sleep. I run the purifiers on high until bedtime, then use the remote to downshift, turning the unit down during the night.