honeywell f50f air cleaner manual

The service from the vendor, DtiCorp was great. The DCP 300 is a microprocessor-based ¼ DIN controller programmer that combines high functionally, quality and reliability at a great price. It supports up to 19 program profiles with up to 30 segments per profile. A universal input accepts thermocouple signals, resistance temperature detector (RTD) signals, DC Voltages and DC currents. DCP 301 is a single channel programmer with one input and one loop of control, white the DCP 302 is a dual channel programmer with two inputs and two loops of control. A temperature and relative humidity calculation model is available on the DCP 302. The DCP 300 supports extensive digital I/O functions including 3 event outputs, 5 time events (optional), and up to 12 external switch inputs (8 of those are optional). Up to two auxiliary outputs can be added as options on certain models of the DCP 301. The DCP 302 has one optional auxiliary output available on certain models. • Programs/Segments: A maximum of 19 program profiles can be stored and up to 30 Segments can be programmed to each profile.

• Accurate: Input #1 accuracy is 0.1%FS, and input #2 accuracy is 0.2%FS. The high sampling time is 0.1 seconds. • Flexible: The DCP 300 can operate on any line voltage from 90 VAC to 264 VAC at 50/60 Hz. Input #1 is a universal input that can be field selectable for a number of different thermocouples, RTD, and linear inputs. • Digital Inputs: Up to 12 external switch inputs (4 standard and 8 optional) allow remote selection of program numbers or operation. • Event and Auxiliary Outputs: Three event relay outputs (standard) are available for PV, deviation, controller mode, or other state indications. Five time events (optional) of open collector outputs are also available for indication of time events and segment number events. Two auxiliary outputs are optionally available on certain models of the DCP 301, with one available on certain models of the DCP 302. CE Mark CD mark compliant applicable standards; Select a link under the "item" tab below to order. Table 1Table 2Table 3Table 4Table 5Table 6XXXXXXXXXXXXTable 1KEY NUMBERP3011 Channel Digital Controller/ProgrammerP3022 Channel Digital Controller/ProgrammerTable 2Outputs-Channel 10DRelay (5 Amp)2GPosition Proportional5GCurrent (4 - 20 mA)3DRelay/Relay (Heat/Cool)5KCurrent/Current (Heat/Cool)Table 3Inputs0One Input Channel1Two Input Channels2Temperature/Relative Humidity CalculationTable 4PowerESUniversal Power - 90 to 264 VAC, 50/60 HzTable 5Option 100None011 Auxiliary Output022 Auxiliary OutputsTable 6Option 20None112 Digital Inputs + 3 Events + 5 Time Events

30 per program maximum RAMP-X system: Set by setpoints (SP1, SP2) and time. 0 to 99 hours 59 minutes; or 0 to 99 minutes 59 seconds (time unit selectable) ± 0.01 % (0.1 second delay when segment time setting is 0) Sets ON and OFF times. PID Set Number(each channel)
clean dinair airbrush gun Sets 0 to 8.
angelcare air purifier price(Set 0 for continuation of previous segment.)
nasa airocide air purifier(Set 0 to 4 on heat/cool models.) Sets G.Soak width 0 units to 1000 units. Sets program ON/OFF and channel. Sets program count 0 to 9999. Sets program number 0 to 19 (0: no link). Sets 8 alphanumerics for each program (not displayed on controller). Thermocouple disconnection detection allowable parallel resistance: 1 M-Ohm minimum

Thermocouple, dc voltage input: –5 Vdc to +15 VdcDC current input: 50 mA dc; Upscale and downscale can be internally selected. (DC current input and dc voltage input ranges of 1 V or more are only downscaled.) 110 % FS minimum: Upscale–10 % FS maximum: Downscale (Note that F50 range is not downscaled. Lower readout limit of B18 range is 20 °C.) Cold Junction Compensation System Internal/external (0 °C only) compensation selectable –1999 units to +9999 units (Settable by dc voltage and dc current. Reverse scaling and decimal point repositioning possible.) Dropout 0.1 % to 10.0 %. Possible by dc current and voltage ranges. 12 (both line ends fixed, 11 points variable) –1000 units to +1000 units variable 0.0 sections to 120.0 seconds variable (filter OFF at 0.0) The Man-Dirk group of companies are specialist suppliers of tools and equipment in the maintenance, repair and operating (MRO) product groupings to mining, industry, power generation, municipalities, government and quasi-government departments.

Man-Dirk’s extensive branch network, product range (primarily, proprietary brands), catalogues, IT network and highly experienced staff have enabled the company to deliver fit for use industrial products at the right time, at competitive pricing directly to customer operations.Man-Dirk is a level 2 BBBEE company, owned 100% by Humulani Marketing. Man-Dirk is an associate BMG Company which is part of Invicta Holdings Ltd.Makona, Man-Dirk’s 66.6% owned enterprise development company initiative is 50.12% black owned .Of this 50.12% black ownership, 40. 88% is black woman owned. Further, Makona is a level 2 BBBEE Company. Head Office – Randfontein 14 Bussing Road, AureusRandfontein, 1760 P.O. Box 1093Randfontein, 1760 Tel: +27 11 412 1020Fax: +27 11 692 1714e-Mail : This email address is being protected from spambots. We have 69 guests and no members onlineLogin to your account Don't have an account yet? Mayer Air Fryer WHITE (MMAF2) Say NO to oily food and save yourself from the unhealthy oils, heat and the messy cleaning;